The PL PETR sensor allows for the use of one process connection and one transmitter for measuring multiple process variables. The PL PETR sensor measures pH, ORP, and temperature. Using a PL PETR sensor will reduce installation and maintenance costs.
The PL PETR sensor allows for the use of one process connection and one transmitter for measuring multiple process variables. The PL PETR sensor measures pH, ORP, and temperature.
Using a PL PETR sensor will reduce installation and maintenance costs.
pH | 0…14 |
ORP | -1500…1500 mV |
Temperature | 32…266 °F (0…130 °C) |
Pressure | 14.5…180 psig (1…12 bar) |
Length | 120. 225, 325, or 425 mm |
Process connection | PG 13.5 |
pH sensor material | H-glass |
ORP sensor material | Platinum disk |
Sensor cap | VarioPin |
Junction | Open Hole (2x) |
Reference system | Ag/AgCl with Duralid polymer electrolyte |
Temperature detector | Pt 1000 |
pH |
0…14 |
ORP |
-1500…1500 mV |
Temperature |
32…266 °F (0…130 °C) |
Pressure |
0…145 psig (0…10 bar) |
Length |
120 or 225 mm |
Process connection |
PG 13.5 |
pH sensor material |
Alpha glass |
ORP sensor material |
Platinum ring |
Sensor cap |
Memosens® |
Junction |
Hole (2x) |
Reference system |
Ag/AgCl, polymer electrolyte |
Temperature detector |
NTC 30 kΩ |
ATEX certificate |
II 1/2 G Ex ia IIC T3/T4/T6 |
FM approvals (US & C) |
IS for Cl I, Div 1, Gp ABCD; Cl I, Zone 0, Aex/Ex ia IIC T6…T4 NIFW for Cl I, Div 2, Gp ABCD; Cl I, Zone 2, IIC T6…T4 |
Title | Type | |
---|---|---|
VarioPin Analog Cable | Manual | DOWNLOAD |
DOWNLOAD | ||
Sensor Protection | Manual | DOWNLOAD |
DOWNLOAD | ||
PL PETR Spec Sheet | Technical Specifications | DOWNLOAD |
DOWNLOAD | ||
Sensor Application Data Sheet | Application Data Sheet | DOWNLOAD |
DOWNLOAD |
Don’t be limited by your equipment, start using pain-free instrumentation & keep production moving.
The PL PETR sensor allows for the use of one process connection and one transmitter for measuring multiple process variables. The PL PETR sensor measures pH, ORP, and temperature.
Using a PL PETR sensor will reduce installation and maintenance costs.
pH | 0…14 |
ORP | -1500…1500 mV |
Temperature | 32…266 °F (0…130 °C) |
Pressure | 14.5…180 psig (1…12 bar) |
Length | 120. 225, 325, or 425 mm |
Process connection | PG 13.5 |
pH sensor material | H-glass |
ORP sensor material | Platinum disk |
Sensor cap | VarioPin |
Junction | Open Hole (2x) |
Reference system | Ag/AgCl with Duralid polymer electrolyte |
Temperature detector | Pt 1000 |
pH |
0…14 |
ORP |
-1500…1500 mV |
Temperature |
32…266 °F (0…130 °C) |
Pressure |
0…145 psig (0…10 bar) |
Length |
120 or 225 mm |
Process connection |
PG 13.5 |
pH sensor material |
Alpha glass |
ORP sensor material |
Platinum ring |
Sensor cap |
Memosens® |
Junction |
Hole (2x) |
Reference system |
Ag/AgCl, polymer electrolyte |
Temperature detector |
NTC 30 kΩ |
ATEX certificate |
II 1/2 G Ex ia IIC T3/T4/T6 |
FM approvals (US & C) |
IS for Cl I, Div 1, Gp ABCD; Cl I, Zone 0, Aex/Ex ia IIC T6…T4 NIFW for Cl I, Div 2, Gp ABCD; Cl I, Zone 2, IIC T6…T4 |
Title | Type | |
---|---|---|
VarioPin Analog Cable | Manual | DOWNLOAD |
DOWNLOAD | ||
Sensor Protection | Manual | DOWNLOAD |
DOWNLOAD | ||
PL PETR Spec Sheet | Technical Specifications | DOWNLOAD |
DOWNLOAD | ||
Sensor Application Data Sheet | Application Data Sheet | DOWNLOAD |
DOWNLOAD |
Don’t be limited by your equipment, start using pain-free instrumentation & keep production moving.
![]() |
Thank you for Signing Up |
© 2025 All Rights Reserved. M4 Knick