SE 515
pH Sensor for Water

The SE 515 Memosens pH sensor is ideal for use in water and wastewater treatment applications.
  • Low-maintenance gel electrolyte does not require refilling
  • Fast response time in both low temperature and low ionic environments
  • Stable measurements even with suspended solids and algae
Description

The SE 515 is the ideal pH sensor for water and wastewater treatment applications. The Memosens sensor is designed to withstand plugging media, low temperatures, and be reliable in low-ionic media. Additionally, an integrated NTC 30K temperature element assures that all pH measurements are accurately compensated for the process media temperature. The sensor’s gel electrolyte does not require refilling, making this a low-cost and low-maintenance pH sensor for water and wastewater applications.
 
The SE 515 is suitable for use with any Memosens transmitter. However, when paired with the MemoRail transmitter, it provides one of the lowest-priced digital pH measurement loops on the market.
 

Applications for the SE 515 Water pH Sensor

  • Raw water
  • Chlorine pretreatment
  • Coagulation optimization
  • Flocculation
  • Clarifier
  • Effluent monitoring
 

SE 515 with Memosens Technology

Memosens sensors provide several benefits with regard to ease of use and reduction of operating costs:
 
  • Submersible inductive connection removes measurement influence from moisture and humidity that are commonly present in water and wastewater applications.
  • Galvanically isolated so there is no measurement influence from noise or ground loops. This is especially beneficial in open basins when using plastic holders.
  • Technicians can perform calibrations and diagnostics in the shop or lab. As a result, this reduces field maintenance time and process downtime.
 

Complete Your Loop...

Temp Range: 23 … 248 °F
Pressure Range: 100 psi at 176 °F 50 psi at 248 °F
Temp Range: 23 … 248 °F
Pressure Range: 100 psi at 176 °F 50 psi at 248 °F
ProgaLog 4000 is a PC software for offline configuration of Protos 4400 and Stratos Multi Transmitters.
  • Spend less time in the field doing configurations or modifications
  • Easily configure every transmitter the same way
ProgaLog 4000 is a PC software for offline configuration of Protos 4400 and Stratos Multi Transmitters.
  • Spend less time in the field doing configurations or modifications
  • Easily configure every transmitter the same way
Temp: 32 … 302 °F

Pressure: Max. 145 psi

Range: 0 … 1,000 mS/cm
Temp: 32 … 302 °F

Pressure: Max. 145 psi

Range: 0 … 1,000 mS/cm
Temp Range: 5…275°F

Pressure Range: -2.9 … 145 psi

pH Range: 0 … 14
Temp Range: 5…275°F

Pressure Range: -2.9 … 145 psi

pH Range: 0 … 14
Temp Range: Max. 194°F

Pressure Range: Max. 90 psi
Temp Range: Max. 194°F

Pressure Range: Max. 90 psi
Temp Range: –4 … 320°F

Pressure Range: Max. 362 psi
Temp Range: –4 … 320°F

Pressure Range: Max. 362 psi
Temp: 14 … 248 °F

Pressure: -14.5 … 232 psi

Range: 0 … 1,000 µS/cm
Temp: 14 … 248 °F

Pressure: -14.5 … 232 psi

Range: 0 … 1,000 µS/cm
Temp Range: 316L SS: 23… 248°F PP: 23 … 176°F PVDF: 23 … 212°F
Pressure Range: 316L SS: 0…50 psi CPVC: 50 psi PVDF: 50 psi
Temp Range: 316L SS: 23… 248°F PP: 23 … 176°F PVDF: 23 … 212°F
Pressure Range: 316L SS: 0…50 psi CPVC: 50 psi PVDF: 50 psi
The M4 Knick CP compact panels are designed to condition applications with elevated temperature and pressure. Once the sample has been conditioned, it can be sent to the analyzers for continuous measurement and/or to take a manual sampling.
  • Includes Memosens measurement technology
  • Conditioning according to the ASME PTC 19.11
  • Plug and play into existing systems
  • Pre-tubed
The M4 Knick CP compact panels are designed to condition applications with elevated temperature and pressure. Once the sample has been conditioned, it can be sent to the analyzers for continuous measurement and/or to take a manual sampling.
  • Includes Memosens measurement technology
  • Conditioning according to the ASME PTC 19.11
  • Plug and play into existing systems
  • Pre-tubed
SC sample coolers provide the most cooling efficiency, allowing them to be suitable for most liquid, gas, or steam processes.
  • Available as a component or part of a full conditioning panel
  • Ideal for boiler water and steam applications
  • Double helicoidal coil
  [vc_row][vc_column width=”1/1″][prk_wp_theme_button type=”theme_button_inverted medium” prk_in=”Request a Quote” link=”https://m4knick.com/contact-m4-knick/#form”][/vc_column][/vc_row]
SC sample coolers provide the most cooling efficiency, allowing them to be suitable for most liquid, gas, or steam processes.
  • Available as a component or part of a full conditioning panel
  • Ideal for boiler water and steam applications