ARF 220

Plastic Flow-through Fitting for SE 610 Conductivity Sensor

Complete Your Loop...

Uniclean 720 Automated Cleaning System
Systems, Automated Cleaning and Calibration

Uniclean 720/730

Electro-pneumatic Controller for Automatic Cleaning
The Uniclean 720 and 730 is a control boxes for a simple electro-pneumatic cleaning system for pH, ORP, conductivity, and dissolved oxygen sensors.
Temp Range: 14…158 °F
Learn More
The Uniclean 720 and 730 is a control boxes for a simple electro-pneumatic cleaning system for pH, ORP, conductivity, and dissolved oxygen sensors.
Temp Range: 14…158 °F
The Uniclean 720 and 730 is a control boxes for a simple electro-pneumatic cleaning system for pH, ORP, conductivity, and dissolved oxygen sensors.
Temp Range: 14…158 °F
CSR 425 1 Inch Ball Valve Retractable holder
Retractable Holders

CSR 425

1″ Ball Valve Retractable Holder
Temp Range: 23 … 248 °F
Pressure Range: 100 psi at 176 °F 50 psi at 248 °F
Learn More
Temp Range: 23 … 248 °F
Pressure Range: 100 psi at 176 °F 50 psi at 248 °F
Temp Range: 23 … 248 °F
Pressure Range: 100 psi at 176 °F 50 psi at 248 °F
ProgaLog 4000
Software

ProgaLog 4000

Transmitter Configuration Software
ProgaLog 4000 is a PC software for offline configuration of Protos 4400 and Stratos Multi Transmitters.
  • Spend less time in the field doing configurations or modifications
  • Easily configure every transmitter the same way
Learn More
ProgaLog 4000 is a PC software for offline configuration of Protos 4400 and Stratos Multi Transmitters.
  • Spend less time in the field doing configurations or modifications
  • Easily configure every transmitter the same way
ProgaLog 4000 is a PC software for offline configuration of Protos 4400 and Stratos Multi Transmitters.
  • Spend less time in the field doing configurations or modifications
  • Easily configure every transmitter the same way
K24 4-Electrode Conductivity Sensor
Sensors, Conductivity

K25

4-Electrode Conductivity Sensor for Heavily Polluted and Fibrous Media
Temp: 32 … 302 °F
 
Pressure: Max. 145 psi
 
Range: 0 … 1,000 mS/cm
Learn More

K25

Temp: 32 … 302 °F
 
Pressure: Max. 145 psi
 
Range: 0 … 1,000 mS/cm

K25

Temp: 32 … 302 °F
 
Pressure: Max. 145 psi
 
Range: 0 … 1,000 mS/cm
SE 547 ISFET pH Sensor
Sensors, pH

SE547

ISFET Memosens pH Sensor
Temp Range: 5…275°F
Pressure Range: -2.9 … 145 psi
pH Range: 0 … 14
Learn More
Temp Range: 5…275°F
Pressure Range: -2.9 … 145 psi
pH Range: 0 … 14
Temp Range: 5…275°F
Pressure Range: -2.9 … 145 psi
pH Range: 0 … 14
WA 111 Plastic Pneumatic Retractable Holder
Retractable Holders

WA 111

Plastic Pneumatic Retractable Holder
Temp Range: Max. 194°F
Pressure Range: Max. 90 psi
Learn More
Temp Range: Max. 194°F
Pressure Range: Max. 90 psi
Temp Range: Max. 194°F
Pressure Range: Max. 90 psi
CSF 625 Flow Through Fitting
Flow-Through

CSF 625

Stainless Steel Flow-Through Fitting
Temp Range: –4 … 320°F
Pressure Range: Max. 362 psi
Learn More
Temp Range: –4 … 320°F
Pressure Range: Max. 362 psi
Temp Range: –4 … 320°F
Pressure Range: Max. 362 psi
SE 625 Conductivity Sensor
Sensors, Conductivity

SE625

Coaxial Conductivity Sensor for Low-Conductivity Water
Temp: 14 … 248 °F
Pressure: -14.5 … 232 psi
Range: 0 … 1,000 µS/cm
Learn More
Temp: 14 … 248 °F
Pressure: -14.5 … 232 psi
Range: 0 … 1,000 µS/cm
Temp: 14 … 248 °F
Pressure: -14.5 … 232 psi
Range: 0 … 1,000 µS/cm
CSR 120 retractable holder with pH sensor
Retractable Holders

CSR 120

Simple Retractable Holder for 120 mm Sensors
Temp Range: 316L SS: 23… 248°F PP: 23 … 176°F PVDF: 23 … 212°F
Pressure Range: 316L SS: 0…50 psi CPVC: 50 psi PVDF: 50 psi
Learn More
Temp Range: 316L SS: 23… 248°F PP: 23 … 176°F PVDF: 23 … 212°F
Pressure Range: 316L SS: 0…50 psi CPVC: 50 psi PVDF: 50 psi
Temp Range: 316L SS: 23… 248°F PP: 23 … 176°F PVDF: 23 … 212°F
Pressure Range: 316L SS: 0…50 psi CPVC: 50 psi PVDF: 50 psi
CP Compact Panel Sample Conditioning
Panels

CP Compact Panel

Sample Conditioning Panel
The M4 Knick CP compact panels are designed to condition applications with elevated temperature and pressure. Once the sample has been conditioned, it can be sent to the analyzers for continuous measurement and/or to take a manual sampling.
  • Includes Memosens measurement technology
  • Conditioning according to the ASME PTC 19.11
  • Plug and play into existing systems
  • Pre-tubed
Learn More
The M4 Knick CP compact panels are designed to condition applications with elevated temperature and pressure. Once the sample has been conditioned, it can be sent to the analyzers for continuous measurement and/or to take a manual sampling.
  • Includes Memosens measurement technology
  • Conditioning according to the ASME PTC 19.11
  • Plug and play into existing systems
  • Pre-tubed
The M4 Knick CP compact panels are designed to condition applications with elevated temperature and pressure. Once the sample has been conditioned, it can be sent to the analyzers for continuous measurement and/or to take a manual sampling.
  • Includes Memosens measurement technology
  • Conditioning according to the ASME PTC 19.11
  • Plug and play into existing systems
  • Pre-tubed

Ready for a convenient measurement solution?

Don’t be limited by your equipment, start using pain-free instrumentation & keep production moving.

ARF 220