Stratos Multi with EtherNet/IP

Setup of Stratos Multi with Ethernet/IP

Learn how to quickly set up and configure the EtherNet/IP settings on your Stratos Multi analytical transmitter. The Value of EtherNet/IP If you’re utilizing an Ethernet / IP network infrastructure within your plant, you probably already understand the value this protocol. But are you utilizing this protocol for your liquid analytical measurement loops? The Stratos […]

Stratos Multi Setup and Configuration

Stratos Multi Setup Video

Learn how to quickly set up and configure your Stratos Multi transmitter for pH, ORP, conductivity, and oxygen sensors. Before Configuration Before you begin, make sure you connect your power supply, sensor cables, and any outputs you are utilizing to the terminal box on the back of the transmitter. After applying power, you will notice […]

Stratos Multi Favorites Menu

Stratos Multi Favorites Menu Video

Learn how to setup your favorites menu in the Knick Stratos Multi transmitter, and see which favorites items we suggest to add for quick sensor data access. Favorites Menu One of the great features about the Stratos Multi transmitter is the ability to save different items as favorites for quick and easy access from the […]

Stratos Multi Offline pH Calibration

Stratos Multi pH Calibration Video

Learn how to do an offline calibration on Memosens pH sensor with auto-calibration on the Stratos Multi. Offline Calibration We will perform the calibration offline in a controlled environment right here in our workshop. Our connected pH sensor is a Memosens smart digital sensor. The calibration will be written and stored in the head of […]

Stratos Multi – Troubleshooting your Loop

Troubleshooting Stratos Multi Video

Take a look at the diagnostic and troubleshooting capabilities of the Knick Stratos Multi. Intuitive Diagnostics The Stratos Multi transmitter provides intuitive diagnostics, along with the multi-color backlit display which indicates the operating state of the measurement loop. A change in the screen color clearly indicates status, along with the corresponding Namur NE 107 icon […]

Stratos Multi Transmitter Overview

Stratos Multi Overview Video

Learn about the Stratos Multi transmitter for pH, ORP, conductivity and oxygen sensors and see what the box includes. Transmitter Overview The Multi is a 4-wire transmitter capable of taking up to two sensors for the measurements of pH, ORP, conductivity, or dissolved oxygen in any combination. It is available with Class 1 Division 2 […]

Stratos Evo Transmitter Overview

Stratos Evo Overview

See what is included when you unbox your Stratos Evo, and get an overview of the terminal block, keypad, and multi-color display. Stratos Evo Overview Today I’m going to give you an overview of the Stratos Evo multi-parameter transmitter from Knick. The Stratos Evo is a general purpose 4-wire transmitter capable of taking up the […]

Stratos Evo Setup and Configuration

Setup and Configuration of Stratos Evo

Let’s walk through the Knick Stratos Evo setup and configuration at 50 West Brewery in Cincinnati, OH. This Memosens pH loop will be measuring and control the acid dosing of the incoming water. This ensures the water is within specification prior to the start of the brewing process. Stratos Evo Setup Before you begin, ensure […]

Offline pH Calibration Using the Stratos Evo Transmitter

Calibrate with Stratos Evo

Walk through the steps to perform an automatic two-point pH calibration using the Stratos Evo transmitter from Knick with a Memosens pH sensor. Memosens Benefits The main benefit of using Memosens digital sensors is that the calibration data stores in the sensor head and not in the transmitter. This allows us to save time by […]

Stratos Evo: Error 60

Error 60 on a Stratos Evo

Understand what an Error 60 means and how to fix it on the Stratos Evo. Error Code 60 Errors are clearly indicated with the change in screen color along with the corresponding code in the bottom left corner. Here you can see that our Stratos Evo is displaying error code 60. The screen has turned […]