products

Measurement
Solutions

Search

Categories

Filter Label
Conductivity 
Sensors 
Ex Approvals
CIP/SIP Capable
SE 604 Conductivity Sensor

SE604

Coaxial Sensor for Ultrapure Water
Temp: -4…248 °F
Pressure: 362 psi @ -4…158°F; Max. 145 psi @ 248°F
Range: 0.04…500 µS/cm
Learn More
Temp: -4…248 °F
Pressure: 362 psi @ -4…158°F; Max. 145 psi @ 248°F
Range: 0.04…500 µS/cm
Temp: -4…248 °F
Pressure: 362 psi @ -4…158°F; Max. 145 psi @ 248°F
Range: 0.04…500 µS/cm
SE605 Conductivity Sensor

SE605

Coaxial Conductivity Sensor for Low-Conductivity Water
Temp: 14 °F…248 °F
Pressure:
Ingold: -14.5…363 psig; @ –4…158 °F
Tri-Clamp: -14.5…232 psig; @ 14…230 °F
Range: 0.04…1,000 µS/cm
Learn More
Temp: 14 °F…248 °F
Pressure:
Ingold: -14.5…363 psig; @ –4…158 °F
Tri-Clamp: -14.5…232 psig; @ 14…230 °F
Range: 0.04…1,000 µS/cm
Temp: 14 °F…248 °F
Pressure:
Ingold: -14.5…363 psig; @ –4…158 °F
Tri-Clamp: -14.5…232 psig; @ 14…230 °F
Range: 0.04…1,000 µS/cm
Tricamp SE605H Conductivity Sensors

SE605H

Hygienic Coaxial Conductivity Sensor for Low-Conductivity Water
Temp: -4 … 275 °F
Pressure:
Ingold: 0…362 psig; @ –4…158 °F
Tri-Clamp: 0…232 psig; @ -4…230 °F
Range: 0 … 1,000 µS/cm
Learn More
Temp: -4 … 275 °F
Pressure:
Ingold: 0…362 psig; @ –4…158 °F
Tri-Clamp: 0…232 psig; @ -4…230 °F
Range: 0 … 1,000 µS/cm
Temp: -4 … 275 °F
Pressure:
Ingold: 0…362 psig; @ –4…158 °F
Tri-Clamp: 0…232 psig; @ -4…230 °F
Range: 0 … 1,000 µS/cm
SE 630 Conductivity Sensor

SE630

Corrosion-Resistant Conductivity Sensor
Temp: -4…275 °F
Pressure: 0…232 psig
Range: Analog 10 µS/cm…50 mS/cm
Memosens 0 …n0 mS/cm
Learn More
Temp: -4…275 °F
Pressure: 0…232 psig
Range: Analog 10 µS/cm…50 mS/cm
Memosens 0 …n0 mS/cm
Temp: -4…275 °F
Pressure: 0…232 psig
Range: Analog 10 µS/cm…50 mS/cm
Memosens 0 …n0 mS/cm

products

Measurement
Solutions

Conductivity 
Sensors 
SE 604 Conductivity Sensor

SE604

Coaxial Sensor for Ultrapure Water
Temp: -4…248 °F
Pressure: 362 psi @ -4…158°F; Max. 145 psi @ 248°F
Range: 0.04…500 µS/cm
Learn More
Temp: -4…248 °F
Pressure: 362 psi @ -4…158°F; Max. 145 psi @ 248°F
Range: 0.04…500 µS/cm
Temp: -4…248 °F
Pressure: 362 psi @ -4…158°F; Max. 145 psi @ 248°F
Range: 0.04…500 µS/cm
SE605 Conductivity Sensor

SE605

Coaxial Conductivity Sensor for Low-Conductivity Water
Temp: 14 °F…248 °F
Pressure:
Ingold: -14.5…363 psig; @ –4…158 °F
Tri-Clamp: -14.5…232 psig; @ 14…230 °F
Range: 0.04…1,000 µS/cm
Learn More
Temp: 14 °F…248 °F
Pressure:
Ingold: -14.5…363 psig; @ –4…158 °F
Tri-Clamp: -14.5…232 psig; @ 14…230 °F
Range: 0.04…1,000 µS/cm
Temp: 14 °F…248 °F
Pressure:
Ingold: -14.5…363 psig; @ –4…158 °F
Tri-Clamp: -14.5…232 psig; @ 14…230 °F
Range: 0.04…1,000 µS/cm
Tricamp SE605H Conductivity Sensors

SE605H

Hygienic Coaxial Conductivity Sensor for Low-Conductivity Water
Temp: -4 … 275 °F
Pressure:
Ingold: 0…362 psig; @ –4…158 °F
Tri-Clamp: 0…232 psig; @ -4…230 °F
Range: 0 … 1,000 µS/cm
Learn More
Temp: -4 … 275 °F
Pressure:
Ingold: 0…362 psig; @ –4…158 °F
Tri-Clamp: 0…232 psig; @ -4…230 °F
Range: 0 … 1,000 µS/cm
Temp: -4 … 275 °F
Pressure:
Ingold: 0…362 psig; @ –4…158 °F
Tri-Clamp: 0…232 psig; @ -4…230 °F
Range: 0 … 1,000 µS/cm
SE 630 Conductivity Sensor

SE630

Corrosion-Resistant Conductivity Sensor
Temp: -4…275 °F
Pressure: 0…232 psig
Range: Analog 10 µS/cm…50 mS/cm
Memosens 0 …n0 mS/cm
Learn More
Temp: -4…275 °F
Pressure: 0…232 psig
Range: Analog 10 µS/cm…50 mS/cm
Memosens 0 …n0 mS/cm
Temp: -4…275 °F
Pressure: 0…232 psig
Range: Analog 10 µS/cm…50 mS/cm
Memosens 0 …n0 mS/cm
Technology
Ex Approvals
CIP/SIP Capable